How to handle a no-heat call
Record the temperature, separate a thermostat mistake from a dead furnace, and book the vendor the same night if the unit is below the local minimum.
On this page
The short answer
Handle a no-heat call by recording the indoor temperature in the first hour, separating a thermostat mistake from a dead furnace, and booking a vendor the same night when the unit is below the local minimum. Keep a written cap on the invoice, and do not use an unvented fuel heater as a substitute. This is an operations routine for winter 2026 into January 2027, not legal advice. Your city or province sets the temperature you must meet.
Key takeaways
- Write the indoor temperature and the time on a work order during the first call.
- A thermostat or a filthy filter is not the same job as a furnace that will not fire.
- Do not use an unvented fuel heater, an oven, or a grill as temporary heat.
- Pay one vendor invoice to that unit, under the owner's cap, and report the closing temperature the same day.
When a tenant reports no heat, confirm the indoor temperature, check the thermostat and the filter, and open a work order the same hour if the unit is actually cold. Do that through winter 2026 and into January 2027, including nights and weekends. A no-heat call is a temperature problem with a clock on it. It is not a note to handle on Monday if the reading is already below the lease or the local rule.
This is an operations routine, not legal advice. Cities and provinces set their own minimums, and the lease may be stricter. In New York, heat season runs from October 1 through May 31. Between 6 a.m. and 10 p.m., if it is below 55 degrees Fahrenheit outside, the inside must be at least 68. Overnight, the inside must be at least 62 no matter the outdoor temperature. Those figures are from NYC Housing Preservation and Development. Your town may use a different number. Read it before you tell a tenant they are "fine" at 60.
Ready.gov warns that winter storms can cut off heat and power, and that carbon monoxide risk rises when people improvise. Health Canada says you cannot see or smell carbon monoxide, that the indoor risk is greatest in colder months, and that you should leave if a carbon monoxide alarm sounds.

What do you do in the first hour of a no-heat call?
Answer the portal request or the phone call with three questions: what room, what the thermostat is set to, and what it reads right now. Ask whether other units in the building are cold. Ask whether the carbon monoxide alarm is sounding. If it is, tell them to leave and call the fire department. Do not troubleshoot a furnace while an alarm is going.
If the alarm is quiet, ask them to check that the thermostat is set to heat, that the setpoint is above the room temperature, and that the fan is not stuck on a schedule that has the system off. Many "no heat" calls in December are a thermostat in cool, a dead battery, or a switch on the furnace bumped to off during a filter change.
Open the work order while you are still on the call. Record the time, the reported temperature, the unit, who you spoke to, and whether anyone in the unit is an infant, an older adult, or someone who cannot leave. That note decides whether you roll a vendor tonight or at 8 a.m.
If you manage from another city, you still own the first hour. A portal request sitting unread until morning is how a 64-degree complaint becomes a frozen pipe. Set a winter on-call rule now: someone reads no-heat messages the same evening through January 2027.
How do you tell a thermostat problem from a dead furnace?
A thermostat problem is fixed without parts, or with a battery. The system clicks, the setpoint was wrong, or the display is blank. Change the batteries if the model uses them, set it to heat, and wait long enough for the burner or the boiler to fire. Write down the temperature when you arrived and again 30 minutes later. If the room is rising, say so on the work order and close it as a thermostat correction, not as a furnace repair.
A dead furnace does not respond. No blower, no flame, a breaker tripped that trips again, or an error code on the board. ENERGY STAR says a dirty filter slows airflow and can lead to expensive failures. Pull the filter. If it is packed, replace it with the size printed on the old one and see if the unit starts. If it still does not start, stop. You are not the technician. Book the heating vendor and put the filter finding in the order so they do not diagnose a clog you already cleared.
Do not reset a breaker more than once. A second trip means a fault, not a blip. Photograph the error code and the furnace data plate. The vendor needs the model before they load the truck. A wrong part is how a one-hour call becomes a second trip at after-hours rates.
If the building is a boiler and only one unit is cold, check that unit's radiator valve or zone valve before you condemn the boiler. If every unit is cold, the boiler is the work order, and you call the owner while the vendor is on the way. One cold unit and a hot hallway is not a plant failure.
When is no heat an emergency rather than a morning callback?
Treat it as an emergency when the indoor temperature is already below the local minimum, when the forecast overnight will push it lower, or when a vulnerable person is in the unit. Also treat a gas smell, a carbon monoxide alarm, or water leaking from the boiler as an emergency. Those are not waiting for the next business day.
A complaint at 4 p.m. that the apartment is 66 and the local rule is 68 can still be tonight's job if the night low is in the teens. It can be the 8 a.m. slot if the building is holding 67, the system is running, and the tenant agrees. Write which one you chose and why. "Tenant said it can wait until morning, reading 67 at 7:40 p.m., vendor booked 8 a.m." is a record. "Will handle" is not.
Give entry notice the lease and the local rule require, and say you are offering the soonest safe slot. If the tenant will not allow entry, document the refusal, offer a second time, and tell the owner the same night. Do not leave a space heater in the hall as a substitute for access.
What temporary heat is safe to offer?
Safe temporary heat is a listed electric heater, placed on a hard floor, plugged directly into a wall outlet, with three feet of clear space, and never left running in an empty room. Offer it only when the vendor cannot restore heat before the night gets colder, and only with the owner's approval if the agreement says you need it for a purchase.
Unsafe heat is anything that burns fuel indoors without a proper vent: a camp stove, a grill, an oven with the door open, or a generator in a garage. Health Canada notes that fuel-burning appliances can dump carbon monoxide into a home, and that some vents fail during a power outage because the fan is electric. Ready.gov ties the same risk to winter storms. If the power is out and the furnace needs electricity, an unvented burner is not the backup plan. The backup plan is a hotel authorization or a unit that still has heat, if the lease and the owner allow it.
If you approve a hotel night, cap it. One night at a named rate, pending the repair, is an owner decision. Write the cap in the same message that authorizes the vendor. Do not promise three nights on a voicemail.
What does a no-heat repair cost on one unit?
Andre Walsh owns unit 2B at 18 Pine Street. On December 3, 2026 at 6:10 p.m. the tenant reports 61 degrees. The thermostat is set to 70 and the display is lit. The filter is gray but not collapsed. The furnace will not fire, and the board shows a code the vendor recognizes. Andre's available trust balance that afternoon is $1,860.00. His approval cap for after-hours heat calls is $800.00, already on file from the management agreement.
| Line | Vendor | Amount |
|---|---|---|
| After-hours diagnostic, December 3 | Harbor Heat, invoice 908 | $95.00 |
| Inducer motor and gasket | Harbor Heat, same invoice | $410.00 |
| Labor, 1.5 hours at the after-hours rate | Harbor Heat, same invoice | $165.00 |
| Total on invoice 908 | $670.00 |
Check it. $95.00 plus $410.00 is $505.00. $505.00 plus $165.00 is $670.00. That is $130.00 under the $800.00 cap. Pay Harbor Heat $670.00 from the trust account and code every line to 18 Pine, unit 2B. Do not split the diagnostic onto your operating account and the parts onto the owner. One invoice, one property, one statement line the owner can read.
After the payment, $1,190.00 of Andre's balance remains before the management fee and the regular payout. If the fee is due the same week, calculate it from the agreement. Do not take the fee out of the $670.00 repair. The repair is his expense. The fee is yours only when the agreement says you have earned it, and it moves to your operating account on its own line.
The tenant's room was 69 degrees at 9:40 p.m. Write that closing temperature on the work order. A closed order without a temperature is an argument waiting for the next cold night.
What do you send the owner the same day?
Send Andre a short note before you end the shift. Name the unit, the time, the arrival temperature, what failed, what you paid, and the temperature when the vendor left. Four sentences are enough: Unit 2B lost heat at about 6 p.m. on December 3, 2026, reading 61 degrees. Harbor Heat replaced the inducer motor. Invoice 908 was $670.00, under the $800.00 cap, paid from his trust balance. The unit was 69 degrees at 9:40 p.m.
If the repair uncovered a heat exchanger crack or a boiler leak, stop and ask for a new cap. Do not let the vendor keep spending on a replacement the owner has not seen. A cracked exchanger is a different job from an inducer motor, and it does not belong as a quiet extra line on invoice 908.
Keep the portal request attached to the work order so the tenant's words and your readings stay together. The January 2027 statement should show one heating repair at $670.00, described in plain language, not a lump called "maintenance."
Track the call, the vendor link, and the owner statement on the same property. Because the bill in Tivio is tied to the work order, the $670.00 on the owner statement is the same invoice you closed on December 3.
Frequently asked questions
Is every no-heat call an after-hours emergency?
Treat it as an emergency when the indoor reading is below the local minimum, when the night will drive it lower, or when a vulnerable person is in the unit. A mild shortfall with the system still running can wait for the morning slot if the tenant agrees and you write that down.
Can I reset the furnace breaker?
Reset it once if you are at the unit and it is safe to do so. If it trips again, stop and book the vendor. A second trip means a fault. Photograph any error code and the data plate so the technician brings the right part.
What if the tenant will not allow entry?
Offer a second time that still meets the cold-night clock, document the refusal, and tell the owner the same evening. Follow the lease and local notice rules. Do not leave a heater in the hallway as a substitute for access.
Does the management fee come out of the repair invoice?
No. The repair is the owner's expense and stays on that property. The fee is a separate line when the agreement says you have earned it. In the example, Harbor Heat was paid $670 from trust, and the fee was not skimmed from that invoice.